home *** CD-ROM | disk | FTP | other *** search
/ Shareware Overload Trio 2 / Shareware Overload Trio Volume 2 (Chestnut CD-ROM).ISO / dir26 / med9410o.zip / M94A2755.TXT < prev    next >
Text File  |  1994-10-25  |  2KB  |  40 lines

  1.        Document 2755
  2.  DOCN  M94A2755
  3.  TI    Belgian multicentre quality control on the performance of selected
  4.        primer sets for diagnostic HIV-1 PCR. Belgian AIDS Reference
  5.        Laboratories.
  6.  DT    9412
  7.  AU    Vandamme AM; Fransen K; Burtonboy G; Debaisieux L; Marissens D; Rega
  8.        Institute, Leuven, Belgium.
  9.  SO    Int Conf AIDS. 1994 Aug 7-12;10(1):232 (abstract no. PB0359). Unique
  10.        Identifier : AIDSLINE ICA10/94369820
  11.  AB    To evaluate the performance of their diagnostic HIV-1 DNA PCR, 8 Belgian
  12.        AIDS Reference Laboratories established a multicentre quality control.
  13.        The centres tested a set of Belgian and African patient samples,
  14.        collected in Belgium, and the British Medical Research Council (MRC)
  15.        HIV-1 PCR reference reagent kit, containing plasmid HIV-1 DNA at several
  16.        dilutions in human carrier DNA with appropriate negative controls. No
  17.        false positive results were reported. All centres proved to be able to
  18.        detect 1 to 2 copies of HIV-1 DNA. Among the 17 Belgian and African
  19.        HIV-1 seropositives, some centres reported up to 4 indeterminate
  20.        results, mainly due to failure of the SK38-39, SK68-69 (Ou et al. 1988)
  21.        and/or gag881-882 (Simmonds et al. 1990) primers and to a bad performing
  22.        algorithm. Only the H1POL4235-4538 nested pol primer set, developed by
  23.        one of the centres, correctly identified the tested HIV-1 positive and
  24.        negative samples. To improve their performance, the centres decided to
  25.        evaluate these pol primers as a reference primer set and to standardize
  26.        the testing algorithm. On 10 additional Belgian and African patient
  27.        samples, all centres achieved a sensitivity and specificity of 100% when
  28.        adapting a standardized algorithm based on 3 HIV-1 primer sets, one of
  29.        which is the H1POL4235-4538 primer set.
  30.  DE    Africa  Algorithms  Belgium  Comparative Study  DNA Primers/*STANDARDS
  31.        DNA, Viral/*ANALYSIS/GENETICS  False Positive Reactions  Genes, gag
  32.        Genes, pol  Human  HIV Infections/MICROBIOLOGY
  33.        HIV-1/GENETICS/*ISOLATION & PURIF  Polymerase Chain Reaction/*STANDARDS
  34.        Quality Control  Reagent Kits, Diagnostic  Reference Standards
  35.        Sensitivity and Specificity  MEETING ABSTRACT  MULTICENTER STUDY
  36.  
  37.        SOURCE: National Library of Medicine.  NOTICE: This material may be
  38.        protected by Copyright Law (Title 17, U.S.Code).
  39.  
  40.